Mahr/Federal Millimar Inductive Measuring Probes

Brand:   Mahr
ID:
116863
Call for Pricing
Current Stock:

Mahr

Mahr/Federal Millimar Inductive Measuring Probes


Millimar P2004 / P2004 A / P2004 B Inductive Probes

  • Models with or without a compressed air (pneumatic) lifter or with vacuum retraction
  • Measuring pin mounted in ball-bearing guide
  • High linearity over the entire measuring range
  • Excellent electromagnetic shielding (EMC)
  • All probes can be easily converted from axial to radial by mounting a slip on cap, included in the scope of supply


Millimar P2001 Inductive Probe

  • Compact Design
  • Sliding Guide
  • High linearity over the total measuring range
  • Excellent electromagnetic shielding (EMC)


P2004 Specifications:

Item Number 5323010 5323011 5323013 5323014
Compatibility Mahr-VLDT Tesa Marposs Federal
Measuring range from -2 mm
Measuring range up to 2 mm
Distance of lower stop MIN -2.2 mm
Distance of lower stop MAX 0 mm
Distance of upper stop MIN 2.2 mm
Distance of upper stop MAX 4.4 mm
Lifter / retraction Standard model
Measuring force 0,75 N +/- 0,15 N
Increase in measuring force 0,2 N/mm
Sensitivity deviation 0.3 %
Repeatability fw (µm) 0.1 µm
Hysteresis fu (µm) 0.5 µm
Linearity deviation within +/- 0,5 mm 0.4 µm
Linearity deviation within +/- 1,0 mm 1.5 µm
Linearity deviation within +/- 2,0 mm 3 µm
IP protection category IP 64
Cable length 2.5 m
Working temperature 20 °C
Working temperature MIN 10 °C
Working temperature MAX 55 °C
Operating temperature Min -10 °C
Operating temperature Max 80 °C
Temperature coefficient 0.15 µm/°C



P2004 A Specifications:

Item Number 5323020 5323021 5323023 5323024
Compatibility Mahr-VLDT Tesa Marposs Federal
Measuring range from -2 mm
Measuring range up to 2 mm
Distance of lower stop MIN -2.2 mm
Distance of lower stop MAX 0 mm
Distance of upper stop MIN 2.2 mm
Distance of upper stop MAX 4.4 mm
Lifter / retraction Vacuum Lifter
Measuring force 0,75 N +/- 0,15 N
Increase in measuring force 0,2 N/mm
Sensitivity deviation 0.3 %
Repeatability fw (µm) 0.1 µm
Hysteresis fu (µm) 0.5 µm
Linearity deviation within +/- 0,5 mm 0.4 µm
Linearity deviation within +/- 1,0 mm 1.5 µm
Linearity deviation within +/- 2,0 mm 3 µm
IP protection category IP 64
Cable length 2.5 m
Working temperature 20 °C
Working temperature MIN 10 °C
Working temperature MAX 55 °C
Operating temperature Min -10 °C
Operating temperature Max 80 °C
Temperature coefficient 0.15 µm/°C



P2004 B Specifications:

Item Number 5323030 5323031 5323033 5323034
Compatibility Mahr-VLDT Tesa Marposs Federal
Measuring range from -2 mm
Measuring range up to 2 mm
Distance of lower stop MIN -2.2 mm
Distance of lower stop MAX 0 mm
Distance of upper stop MIN 2.2 mm
Distance of upper stop MAX 4.4 mm
Lifter / retraction Compressed Air Retraction (max. 1 bar)
Measuring force depending upon air pressure
Sensitivity deviation 0.3 %
Repeatability fw (µm) 0.1 µm
Hysteresis fu (µm) 0.5 µm
Linearity deviation within +/- 0,5 mm 0.4 µm
Linearity deviation within +/- 1,0 mm 1.5 µm
Linearity deviation within +/- 2,0 mm 3 µm
IP protection category IP 64
Cable length 2.5 m
Working temperature 20 °C
Working temperature MIN 10 °C
Working temperature MAX 55 °C
Operating temperature Min -10 °C
Operating temperature Max 80 °C
Temperature coefficient 0.15 µm/°C



P2001 Specifications:

Item Number 5323040 5323041 5323043 5323044
Compatibility Mahr-VLDT Tesa Marposs Federal
Measuring range from -0.5 mm
Measuring range up to 0.5 mm
Measuring force 0,75 N +/- 0,15 N
Increase in measuring force 0,1 N/mm
Sensitivity deviation 0.3 %
Repeatability fw (µm) 0.15 µm
Hysteresis fu (µm) 0.2 µm
Linearity deviation within +/- 0,1 mm 0.6 µm
Linearity deviation within +/- 0,5 mm 1.5 µm
IP protection category IP 40
Cable length 2.5 m
Working temperature 20 °C
Working temperature MIN 10 °C
Working temperature MAX 55 °C
Operating temperature Min -10 °C
Operating temperature Max 80 °C
Temperature coefficient 0.15 µm/°C

Warning Icon

WARNING: This Product Can Expose You To Materials And/Or Chemicals Which Are Known To The State Of California To Cause Cancer And/Or Reproductive Harm.

Mahr/Federal Millimar Inductive Measuring Probes

Mahr/Federal Millimar Inductive Measuring Probes