Nabertherm Muffle Furnace, Max Temperature 1100 °C, with Flap Door, 9 L Volume, L 9/11/B510, 240V - L-095K1AL
Brand: Nabertherm- SKU:
- L-095K1AL
- ID:
- 972782
| Model | L 9/11 |
| Max Temperature | 1100 °C |
| Volume | 9 L |
| Controller | B510 |
| Voltage | 240V |
| Phase | 1-Phase |
Nabertherm Muffle Furnace, Max Temperature 1100 °C, with Flap Door, 9 L Volume, L 9/11/B510, 240V - L-095K1AL
The muffle furnaces L 3/11 - LT 60/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.
Standard Equipment:
- Tmax 1100 °C or 1200 °C
- Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 60/12) for an optimal temperature uniformity
- Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
- Thermocouple type N (1100 °C) or type S (1200 °C)
- Ceramic heating plates with integral heating element which is safeguarded and easy to replace
- Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
- Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
- Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
- Adjustable air inlet integrated in door (see illustration)
- Exhaust air outlet in rear wall of furnace
- Controller with touch operation B510 (5 programs with each 4 segments) resp. controller R8 for L 1/12 (adjustable for one temperature)
- Solid state relays provide for lownoise operation
- Defined application within the constraints of the operating instructions
- NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Controller Series 500:
The controller series 500 impresses with its unique scope of performance and intuitive operation. In combination with the free “MyNabertherm” smartphone app, the monitoring of the furnace is even easier and more powerful than ever before. The operation and programming takes place via a high-contrast, large touch panel, which shows exactly the information that is relevant at the moment.
Standard Equipment:
- Transparent, graphic display of the temperature curves
- Clear presentation of the process data
- 24 operating languages selectable
- Consistent, attractive design
- Easily understandable symbols for many functions
- Precise and accurate temperature control
- User levels
- Program status display with estimated end time and date
- Documentation of the process curves on USB storage medium in .csv file format
- Service information can be read out via USB stick
- Clear presentation
- Plain text display
- Configurable for all furnace families
- Can be parameterized for the different processes
- “Solar Mode” to utilize electricity from photovoltaic systems with and without a battery
Controller Highlights:
In addition to the well-known and matured controller functions, the new generation offers you some individual highlights. Here is an overview of the most important ones for you:
- Modern Design - Colored display of temperature curves and process data
- Easy Programming - Simple and intuitive program entry via touch panel
- Integrated Help Function - Information on various commands in plain text
- Program Management - Temperature programs can be saved as favorites and in categories
- Segment Player - Detailed overview of process information including setpoint, actual value and switched functions
- Wi-Fi-Capable - Connection with the MyNabertherm app
BASIC CONTROLLER B500/B510
- 5 programs / 4 steps
- Up to 2 settable functions
- Calibration option (10 base points)
- Touchpanel
- NTLog (Real-time clock)
- USB interface
- Languages (DE/EN/FR/IT/ES/RU/DK/NL/PL/PT/SE/CZ/HU/TR/RO/NO/EE/FI/HR/LV/LT/SK/SI/CN)
COMFORT CONTROLLER C540/C550
- Like Basic Controller, but: 10 programs / 20 steps
Additional Equipment:
- Chimney, chimney with fan or catalytic converter (not for L 1 and L 15)
- Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
- Protective gas connection to purge with non-flammable process gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight
- Manual or automatic gas supply system
- Port for thermocouple in the rear wall or in the furnace door
- Process control and documentation via VCD software package for monitoring, documentation and control
- Charging rack with closed or perforated trays for loading the furnace in two levels incl. holder for inserting/removing the trays up to a max. temperature of 800 °C and a max. loading weight per layer of 2 kg for the L(T) 9/11 respectively 3 kg for the L(T) 15/11 respectively 3,5 kg for the L(T) 24/11 and L(T) 40/11
View the Nabertherm Laboratory Furnaces and Ovens Catalog
Specifications:
| Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions (2) in mm | Temperature uniformity of +/− 5K in the empty workspace (5) | Connected load (6) | Electrical | Weight | Heating time | ||||||
| in °C (1) | w | d | h | in l | W | D | H (3) | w | d | h | in kW | connection | in kg | in min (4) | |
| L(T) 3/11 | 1100 | 160 | 140 | 100 | 3 | 385 | 330 | 405+155 | 110 | 50 | 50 | 1.3 | 1-phase | 21 | 41 |
| L(T) 5/11 | 1100 | 205 | 170 | 130 | 5 | 385 | 390 | 460+205 | 170 | 80 | 80 | 2.6 | 1-phase | 27 | 47 |
| L(T) 9/11 | 1100 | 235 | 240 | 170 | 9 | 415 | 455 | 515+240 | 180 | 150 | 120 | 3.3 | 1-phase | 35 | 63 |
| L(T) 15/11 | 1100 | 230 | 340 | 170 | 15 | 415 | 555 | 515+240 | 180 | 250 | 120 | 3.5 | 1-phase | 43 | 74 |
| L(T) 24/11 | 1100 | 280 | 340 | 250 | 24 | 490 | 555 | 580+320 | 230 | 250 | 200 | 4.9 | 3-phase | 52 | 69 |
| L(T) 40/11 | 1100 | 320 | 490 | 250 | 40 | 530 | 705 | 580+320 | 270 | 400 | 200 | 6.5 | 3-phase | 70 | 80 |
| LT 60/11 | 1100 | 380 | 490 | 330 | 60 | 610 | 705 | 660+385 | 290 | 360 | 240 | 9.8 | 3-phase | 83 | 150 |
(1) Recommended working temperature for processes with longer dwell times is 1000 °C (L../11) rsp. 1100 °C (L../12)
(2) External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.
(3) Including opened lift door (LT models)
(4) Heating time of the empty and closed furnace up to Tmax −100 K (connected to 230 V 1/N/PE rsp. 400 V 3/N/PE)
(5) Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C see page 77
(6) The connected load refers to the standard furnace and may increase for a furnace with additional equipment. For furnaces with connection options for multi-range voltages, the connected load applies to the highest permissible connected voltage.
See all Nabertherm Muffle Furnaces, Max Temperature 1100 °C, with Flap Door
For more info, visit www.p65warnings.ca.gov.