PCE Instruments Clamp Meter - PCE-CM-6

Brand:   PCE Instruments
SKU:
PCE-CM-6
ID:
972678
UPC:
4250348735713
callling
$119.00
Current Stock:
Adding to cart… The item has been added

PCE Instruments

PCE Instruments Clamp Meter - PCE-CM-6


Clamp Meter / automatic and manual measurement range selection / NCV and live test / true RMS and LoZ / min, max and hold functions / integrated LED torch


The Clamp Meter is a multifunctional meter for the precise measurement of alternating and direct voltage as well as alternating current that can be measured without direct contact to the line. The Clamp Meter is suitable for measuring resistance, temperature, diodes, continuity, frequencies and capacitance and is particularly useful for diagnosing electrical and electronic components.

For maximum measurement accuracy, the Clamp Meter supports True RMS for non-sinusoidal waveforms and a Low Impedance (LoZ) function to reduce interference. The non-contact voltage test enables reliable detection of voltages in cables and sockets.

The 2-inch LC display ensures clear readability, even under poor lighting conditions and an integrated LED torch makes it easier to work in dark environments. The device also offers automatic and manual measurement range selection, allowing it to be flexibly adapted to different measuring situations. Other functions include overload protection, data hold, min, max and an automatic power-off after 15 minutes to conserve battery life. The power-off can also be deactivated for longer measurements.

Compact and easy to use, the Clamp Meter is ideal for electrical installations, maintenance work and use in automation technology. It enables safe and efficient measurements, often without direct intervention in the circuit.


Features:

  • Display range: 6000 counts
  • Measurement range selection: automatic and manual
  • Min, max and hold function
  • 2-inch LC display
  • Integrated LED torch
  • Automatic power-off

Delivery Scope:

  • 1 x Clamp Meter PCE-CM 6
  • 1 x set of test leads
  • 1 x K-type thermocouple
  • 3 x 1.5 V AAA battery
  • 1 x carrying case
  • 1 x user manual

View the PCE-CM-6 User Manual


Specifications:

Direct voltage DC
Measurement range up to   0.1 ... 600 mV
Resolution   0.1 mV
Accuracy   ±(0.5% of Rd +5 digits)
Overload   1000V
   
Direct voltage DC
Measurement range up to   600 mV ... 6V
Resolution   0.001V
Accuracy   ±(0.5% of Rd +5 digits)
   
Direct voltage DC
Measurement range up to   6 ... 60V
Resolution   0.01V
Accuracy   ±(0.5% of Rd +5 digits)
   
Direct voltage DC
Measurement range up to   60 ... 600V
Resolution   0.1V
Accuracy   ±(0.5% of Rd +5 digits)
   
Direct voltage DC
Measurement range up to   600 ... 1000V
Resolution   1V
Accuracy   ±(0.8% of Rd +5 digits)
   
Capacity
Measurement range up to   1 ... 10 nF
Resolution   0.001 nF
Accuracy   ±(4.0% of Rd +5 digits)
   
Capacity
Measurement range up to   10 ... 100 nF
Resolution   0.001 nF
Accuracy   ±(4.0% of Rd +5 digits)
   
Capacity
Measurement range up to   100 ... 1000 nF
Resolution   0.01 nF
Accuracy   ±(4.0% of Rd +5 digits)
   
Capacity
Measurement range up to   1000 nF ... 10 µF
Resolution   0.1 nF
Accuracy   ±(4.0% of Rd +5 digits)
   
Capacity
Measurement range up to   10 ... 100 µF
Resolution   0.001 µF
Accuracy   ±(4.0% of Rd +5 digits)
   
Capacity
Measurement range up to   100 ... 1000 µF
Resolution   0.01 µF
Accuracy   ±(4.0% of Rd +5 digits)
   
Capacity
Measurement range up to   1000 µF ... 10 mF
Resolution   0.1 µF
Accuracy   ±(4.0% of Rd +5 digits)
   
Capacity
Measurement range up to   10 ... 100 mF
Resolution   0.001 mF
Accuracy   ±(5.0% of Rd +10 digits)
   
AC voltage
Measurement range up to   0.1 ... 600 mV
Resolution   0.1 mV
Accuracy   ±(0.8% of Rd +5 digits)
Overload   750V
Frequency range   40 ... 1000 Hz
   
AC voltage
Measurement range up to   600 mV ... 6V
Resolution   0.1 mV
Accuracy   ±(0.8% of Rd +5 digits)
Frequency range   40 ... 1000 Hz
   
AC voltage
Measurement range up to   6 ... 60V
Resolution   0.001V
Accuracy   ±(0.8% of Rd +5 digits)
Frequency range   40 ... 1000 Hz
   
AC voltage
Measurement range up to   60 ... 600V
Resolution   0.01V
Accuracy   ±(0.8% of Rd +5 digits)
Frequency range   40 ... 1000 Hz
   
AC voltage
Measurement range up to   600 ... 750V
Resolution   0.1 V
Accuracy   ±(1.0% of Rd +5 digits)
Frequency range   40 ... 1000 Hz
   
Alternating current AC
Measurement range up to   0.1 ... 60 A
Resolution   0.01 A
Accuracy   ±(2.5% of Rd +8 digits) / VFD: ±(5.0% of Rd +10 digits) / INRUSH: ±(5.0% of Rd +10 digits)
Frequency range   40 ... 400 Hz
   
Alternating current AC
Measurement range up to   60 ... 600 A
Resolution   0.1 A
Accuracy   ±(2.5% of Rd +8 digits) / VFD: ±(5.0% of Rd +10 digits) / INRUSH: ±(5.0% of Rd +10 digits)
Frequency range   40 ... 400 Hz
   
Alternating current AC
Measurement range up to   600 ... 1000 A
Resolution   1 A
Accuracy   ±(2.5% of Rd +8 digits) / VFD: ±(5.0% of Rd +10 digits) / INRUSH: ±(5.0% of Rd +10 digits)
Frequency range   40 ... 60 Hz
   
Resistance
Measurement range up to   0.1 ... 600 Ω
Resolution   1 Ω
Accuracy   ±(1.0% of Rd +5 digits)
   
Resistance
Measurement range up to   600 Ω ... 6 kΩ
Resolution   1 Ω
Accuracy   ±(1.0% of Rd +5 digits)
   
Resistance
Measurement range up to   6 ... 60 kΩ
Resolution   0.001 kΩ
Accuracy   ±(1.0% of Rd +5 digits)
   
Resistance
Measurement range up to   60 ... 600 kΩ
Resolution   0.01 kΩ
Accuracy   ±(1.0% of Rd +5 digits)
   
Resistance
Measurement range up to   600 kΩ ... 6 M Ω
Resolution   0.1 kΩ
Accuracy   ±(1.0% of Rd +5 digits)
   
Resistance
Measurement range up to   6 ... 60 M Ω
Resolution   0.001 M Ω
Accuracy   ±(1.0% of Rd +5 digits)
   
Frequency
Measurement range up to   0 ... 10 Hz
Resolution   0.001 Hz
Accuracy   ±(1.0% of Rd +3 digits)
   
Frequency
Measurement range up to   10 ... 100 Hz
Resolution   0.001 Hz
Accuracy   ±(1.0% of Rd +3 digits)
   
Frequency
Measurement range up to   100 ... 1000 Hz
Resolution   0.01 Hz
Accuracy   ±(1.0% of Rd +3 digits)
   
Frequency
Measurement range up to   1000 Hz ... 10 kHz
Resolution   0.1 Hz
Accuracy   ±(1.0% of Rd +3 digits)
   
Frequency
Measurement range up to   10 ... 100 kHz
Resolution   0.001 kHz
Accuracy   ±(1.0% of Rd +3 digits)
   
Frequency
Measurement range up to   100 ... 1000 kHz
Resolution   0.01 kHz
Accuracy   ±(1.0% v.Mw. +3 Digits)
   
Frequency
Measurement range up to   1000 kHz ... 10 MHz
Resolution   0.1 kHz
Accuracy   ±(3.0% v.Mw. +3 Digits)
   
Temperature
Measurement range up to   -20 ... 0°C
Resolution   0.1°C
Accuracy   ±3°C
   
Temperature
Measurement range up to   0 ... 400°C
Resolution   0.1°C
Accuracy   ±1.0% or ±2°C
   
Temperature
Measurement range up to   400 ... 1000°C
Resolution   0.1°C
Accuracy   ±2.0%
   
Temperature
Measurement range up to   -4 ... 32°F
Resolution   1°F
Accuracy   ±6°F
   
Temperature
Measurement range up to   32 ... 752°F
Resolution   1°F
Accuracy   ±1.0% or ±4°F
   
Temperature
Measurement range up to   752 ... 1832°F
Resolution   1°F
Accuracy   ±2.0%
   
General Technical Data
Measuring functions   MIN, MAX, HOLD
Display type   LCD
Display size   2 Inch
Standard(s)   IEC61010-1, IEC 61010-2-032, IEC 61010-2-033
Maximum cable diameter   35 mm / 1.4 in
Automatic power-off   15 min
Automatic power-off can be deactivated   Yes
Safety standard   CAT III 1000V, CAT IV 600V
max. input impedance   10 M Ω
Measurement range selection   Automatic, Manual
Diode test   Test current: approx. 1.5 mA
Test voltage: approx. 1V
Overload protection: 250V
Display range   6000 counts
Protection class (device)   IP20
(Rechargeable) battery   3 x 1.5V AAA battery, Alkali-manganese
Capacity   1200 mAh
Operating conditions   0 ... 40°C / 32 … 104°F , 0 ... 80% RH
Storage conditions   -10 ... 60°C / 14 … 140°F, 0 ... 70% RH
Dimensions ( L x W x H )   240 x 85 x 45 mm / 9.4 × 3.3 × 1.8 in
Weight   327 g / 0.72 lb

Warning Icon

WARNING: This Product Can Expose You To Materials And/Or Chemicals Which Are Known To The State Of California To Cause Cancer And/Or Reproductive Harm.

PCE Instruments Clamp Meter - PCE-CM-6

PCE Instruments Clamp Meter - PCE-CM-6

PCE Instruments Clamp Meter - PCE-CM-6

$119.00