Mitutoyo PC Driven Micro Vickers Hardness Testers HM-210 & HM-220 Type D

Brand:   Mitutoyo
ID:
118593
Call for Pricing
Current Stock:

Mitutoyo

Mitutoyo PC Driven Micro Vickers Hardness Testers
HM-210 & HM-220 Type D

TYPE D - PC Driven Test System with Motorized Stage and Auto Focus


Equipped both with the latest optical system ideal for measuring the dimensions of indentation images and a test-force loading device that lets you set the desired The HM-200 series is ideal for quality control and mechanical characteristic evaluation using Vickers hardness testing of small areas.


Type D Features:

  • Operation using AVPAK - Automatic dimensions by AVPAK eliminates indentation measurement errors.
  • Automatic measurement of indentations
  • Motorized stage and auto focus


Machine Features:

  • The electromagnetic force motor used in the loading mechanism enables the test force to be freely selected (see test force specifications) over the wide range of 0.4903mN to 19610mN (0.05gf to 2 kgf). It is also possible to freely set load dwell times. Now your desire for absolute control over the indentation size in Vickers hardness testing can be satisfied. The HM-200 series always offers the test force most appropriate for the specimen material and shape.

  • The long working distance objectives used enable a very comfortable working distance between the objective and the specimen surface. This, greatly reduces the possibility of collision between the specimen and the objective during focusing operations. (e.g. for 50X objectives: 1.1mm for conventional models, 2.5mm for HM-200 series)

  • Newly-designed ‘MH Plan’ objectives are optimized for measuring indentation images. The lineup includes 6 types of long working distance objectives: 10X, 20X, 50X and 100X for measuring indentation images, and 2X and 5X for enabling wide-range measurement around indentations.

  • LEDs, which have a longer life, produce less heat, consume less power and are more energy efficient than incandescent bulbs, are employed for the illumination system.

  • The motorized turret allows for up to 4 objective lenses and 2 indenter assemblies to be mounted at the same time.

* PC Not Included.



Technical Data:

Test force range:
HM-210A: 9 steps + arbitrary test force
HM-220A: 19 steps + arbitrary test force
Load dwell time: 0 - 999s
Manual XY stage unit
Stage size: 100x100mm
Travel range: 25x25mm
with Digimatic in/mm micrometer heads
Resolution: 0.001mm
Max. specimen height: 133mm (Stage size: 25 x 25mm)
Max. specimen height: 121mm (Stage size: 50 x 50mm)
Max. specimen depth: 160mm (from the center of indenter)
Optical path: 4-port objectives switching system of Infinity-correction optical system
Resolution: 0.01μm (When using objectives of X40 or more)
Data output: Serial interface (RS-232),
Digimatic interface, USB 2.0
Power supply: 39VA 100-125/220-240V AC, 50/60Hz
Dimensions: (W x D x H): 315x671x595mm
Mass: 43kg


System D Technical Data:

Motorized X-Y Stage Travel Max 50 x 50 mm
Travel Min
Table Size 130 x 130 mm
Speed Max 25 mm/ sec
Motorized Focusing Stage Max Range 1.4 mm
Min Unit .1µ
Max Speed 1 mm/ sec
Joystick Controller Functions Functions X and Y Lock out
Axis X,Y and Z (Focus)
Speed Control Adjustable H,M,L
Tester Control Indent, Turret Position
Other Emergency Stop


Specifications:

Model No. HM-210 Type D HM-210 Type D V/K HM-220 Type D HM-220 Type D V/K
Part No. 64AAB380A 64AAB381A 64AAB382A 64AAB383A
Main Unit No. 810-403 810-403 810-408 810-408
Fixed test force(mN) 98.07, 196.1,
294.2, 490.3,
980.7, 1961,
2942, 4903,
9807
(10gf-1000gf)
98.07, 196.1,
294.2, 490.3,
980.7, 1961,
2942, 4903,
9807
(10gf-1000gf)
0.4903, 0.9807,
1.961, 2.942,
4.903, 9.807,
19.61, 29.42,
49.03, 98.07,
196.1, 294.2,
490.3, 980.7,
1961, 2942,
4903, 9807,
19610
(0.05 gf-2kgf)
0.4903, 0.9807,
1.961, 2.942,
4.903, 9.807,
19.61, 29.42,
49.03, 98.07,
196.1, 294.2,
490.3, 980.7,
1961, 2942,
4903, 9807,
19610
(0.05 gf-2kgf)
Arbitrary ≤100 gf in 1 gram
increments,
> 100gf in 10 gram
increments
≤100 gf in 1 gram
increments,
> 100gf in 10 gram
increments
< 1 gf in .1 gf
increments,
≤100 gf in 1 gram
increments,
> 100gf in 10 gram
increments
< 1 gf in .1 gf
increments,
≤ 100 gf in 1 gram
increments,
> 100gf in 10 gram
increments
Test force control Force generation by electromagnetic and automatic control (load, dwell, unload) Force generation by electromagnetic and automatic control (load, dwell, unload) Force generation by electromagnetic and automatic control (load, dwell, unload) Force generation by electromagnetic and automatic control (load, dwell, unload)
Control unit None, By PC None, By PC None, By PC None, By PC
Loading Rate 60 µ/ sec 60 µ/ sec 60 µ/ sec 60 µ/ sec
Load Dwell Time 0-999 sec 0-999 sec 0-999 sec 0-999 sec
Indenter Vickers Vickers and Knoop Vickers Vickers and Knoop
Objective Lens 10x, 50x 10x, 20x, 50x 10x, 50x, 100x 10x, 50x, 100x
Objective turret Motor driven and manual operation Motor driven and manual operation Motor driven and manual operation Motor driven and manual operation
Filar Eye Piece None None None None
CCTV Camera 3 megapixel, 1/2 in 3 megapixel, 1/2 in 3 megapixel 1/2 in 3 megapixel. 1/2 in
Software AVPAK-10 AVPAK-10 AVPAK-10 AVPAK-10


Click to View Brochure for more specifications and optional accessories


Warning Icon

WARNING: This Product Can Expose You To Materials And/Or Chemicals Which Are Known To The State Of California To Cause Cancer And/Or Reproductive Harm.

Mitutoyo PC Driven Micro Vickers Hardness Testers HM-210 & HM-220 Type D

Mitutoyo PC Driven Micro Vickers Hardness Testers HM-210 & HM-220 Type D

Mitutoyo PC Driven Micro Vickers Hardness Testers HM-210 & H…